Sign In | Join Free | My udpf.com
China Sansion Power Electric Co., Ltd. logo
Sansion Power Electric Co., Ltd.
Building A One-stop Service Platform
Verified Supplier

1 Years

Home > Impulse Voltage Generator >

Automatic Digital Control Lightning Impulse Test System For Transformer Insulation

Sansion Power Electric Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Automatic Digital Control Lightning Impulse Test System For Transformer Insulation

Model Number : SXCY

Rated Voltage : ±100 ~ ±4800 kV

MOQ : 1

Stage Voltage : ±100 ~ ±200 kV

Control System : Digital Automatic Control and Data Acquisition

Certification : CE/SGS/EMS/ISO 9001

Impulse Voltage Type : Lightning Impulse Voltage and Switching Impulse Voltage

Place of Origin : China

Generator Structure : Multi Stage Marx Impulse Generator

Delivery Time : 30 Working Days

Impulse Energy : 7.31 ~ 320 kJ

Payment Terms : L/C,T/T,Western Union

Stage Capacitance : 0.325 ~ 1 μF

Packaging Details : Plywood Case

Number of Stages : 1 ~ 24 Stages

Brand Name : Sansion Power

Name : Lightning Impulse Test System

Contact Now

Product Description

SXCY Lightning Impulse Test System

Lightning Impulse Test System for Transformer Insulation Withstand Testing Equipment

The Lightning Impulse Test System is a high-voltage testing solution designed for evaluating the insulation strength of transformers and power equipment under lightning impulse conditions. The system generates standard lightning impulse voltage and switching impulse voltage to simulate transient overvoltage impact in power networks.

Based on multi-stage Marx impulse generator technology, this system provides stable output voltage, accurate waveform control, and reliable test performance. It is widely used in transformer factories, high voltage laboratories, testing centers, and research institutions for insulation withstand verification.

The equipment adopts digital automatic control and data acquisition technology, enabling engineers to control testing procedures, capture impulse waveforms, and analyze test results efficiently. Flexible configuration allows different voltage levels and energy capacities according to customer requirements.

Product Important Parameters
Parameter Specification
Product Type Lightning Impulse Test System
Rated Voltage ±100 ~ ±4800 kV
Impulse Voltage Type Lightning Impulse Voltage and Switching Impulse Voltage
Generator Structure Multi Stage Marx Impulse Generator
Stage Voltage ±100 ~ ±200 kV
Stage Capacitance 0.325 ~ 1 μF
Impulse Energy 7.31 ~ 320 kJ
Number of Stages 1 ~ 24 Stages
Control System Digital Automatic Control and Data Acquisition
Test Objects Transformers and High Voltage Electrical Equipment
Product Applications

The Lightning Impulse Test System is mainly applied for transformer insulation testing, GIS testing, switchgear testing, cable testing, and high voltage equipment performance evaluation. It helps manufacturers and laboratories verify insulation reliability before equipment operation.

Product Advantages
  • Stable Impulse Output: Provides accurate lightning impulse voltage waveform for reliable testing results.
  • Digital Control System: Supports automatic operation, waveform recording, and test data analysis.
  • Flexible Configuration: Voltage level and energy capacity can be customized for different applications.
  • Safety Protection: Includes overvoltage protection, grounding monitoring, and safety interlock functions.
FAQ
Q1: What is a Lightning Impulse Test System used for?
A: It is used to test insulation performance of transformers and high voltage electrical equipment.
Q2: What equipment can be tested?
A: Transformers, GIS, switchgear, cables, and other high voltage components.
Q3: Can the voltage level be customized?
A: Yes, the system supports customized voltage and energy configurations.
Q4: What waveform does the system generate?
A: Standard lightning impulse and switching impulse voltage waveforms.
Q5: Does it support automatic testing?
A: Yes, it uses digital control and data acquisition technology.
Q6: Where is it mainly used?
A: High voltage laboratories, transformer plants, and testing organizations.
Q7: What safety functions are included?
A: Overvoltage protection, grounding monitoring, and safety interlock systems.
Q8: Why is impulse testing important?
A: It helps identify insulation weaknesses and improves equipment reliability.
Automatic Digital Control Lightning Impulse Test System For Transformer Insulation

Product Tags:

Digital Control Lightning Impulse Test System

      

Automatic Lightning Impulse Test System

      

ISO9001 Lightning Impulse Test System

      
Best Automatic Digital Control Lightning Impulse Test System For Transformer Insulation wholesale

Automatic Digital Control Lightning Impulse Test System For Transformer Insulation Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Sansion Power Electric Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)